| CENTRALLY AIR CONDITIONED APARTMENTS : |
| Air conditioning distribution shall be provied as per the standard layout of the apartment. Any changes in the same shall be to the allottees account |
| STRUCTURE RCC- Framed Structure |
Designed for Zone-5 as per IS Code No. IS-1893(PART-I-2002) for earthquake resistance in structures |
| COMMON AREAS |
| FLOORS |
| Building entrance hall & main lift lobbies |
Combination of marble and granite |
| Staircase/service lift lobby |
Terrazo/stone |
| WALLS |
| Building facade |
Exterior paint |
| Building entrance hall & main lift lobbies |
Combination of marble/granite/ceramic cladding, plaster with acrylic emulsion paint/ wall covering |
| STAIRCASES/SERVICE LIFT |
| Plaster with paint |
| APARTMENT AREAS: |
| FLOORS |
| All internal spaces in the apartment, decks, balconies |
Bare concrerte/IPS |
| WALLS |
All internal wall withing the apartment |
Rough plastered and unpainted |
| DOOR & WINDOWS |
| Doors frames & internal door shutters |
No internal door frames and door shutters will be provied |
| Entrance door (main entrance & service entrance doors) |
Commercial flush shutter / moulded skin doors with padlock |
| Hardware |
Brass / steel / powder coated aluminium / anodised aluminium |
Bathrooms/kitchen |
Similar to other rooms. Will not be finished any further |
| SERVICES |
| ELECTRICAL |
| Only PVC conduits will be provided in the ceiling slabs upto drop points. Back-up power equivalent to about 20 KVA for typical apartments, 30 KVA for Pent houses and Duplex(s) per apartment considering 70% load factor, however, DG set capacity calculation shall take into account suitable overall diversity of 60% |
| No light points, fixtures/switches will be provided. |
| PLUMBING / SANITATION |
| Vertical stacks for water supply and drainage will be provied in the shafts with connecting points provided in the toilets/kitchen. |
| Limited copper piping for th connecting points only |
| Internal distribution of water supply and drainage will be done by the customer according to the internal layouts at his own cost |
| Water softening plant for the complex |
| FIRE FIGHTING / DETECTION SYSTEM |
| Fire fighting including sprinklers, and detection system shall be provided as per NBC norms Part IV SP-7 amendent No. 3, January 1997 |
| LIFTS |
| Two numbers of passenger lifts and one service lift will be provided per tower, serving the basement as well |
| CLUB FACILITY |
Multipurpose room, swimming pool and change room, one squash court, two tennis courts, gymnasium, steam & sauna, pantry, pool table, Laundromat, security control room, convenience shop & centralised services. (Facilities areindicative only, subject to change) |
| GENERAL |
| Car calling system or equivalent system. Water outlets and drainage for car washing facility within the complex. Facility for creche / play school with playground |
| Security system CCTV's / monitoring of limited protion of exteriors, periphery, entrance lobbies and the basement . |